National standard building code masonry built fireplaces.
Gas fireplace surround code requirements.
The fireplace surround can consist of a mantel hearth extensions or the parts of the hearth that extend in front and beyond the firebox and the firebox itself.
The standards should ensure that the fireplace will be safe to use for many years to come.
A masonry metal pre fab or gas fireplace gets hot the surround shouldn t be affected by that heat.
6 152mm 30 1 2 775mm t op of unit min.
In addition if the side panels of your mantel project more than 1 1 2 inches from the fireplace facing you will need additional clearance equal to this.
Builders and do it yourself masons in california must follow building codes when they plan to install a fireplace in a residential or commercial property.
When you wish to install or build a new fireplace you need to take into account code requirements for fireplace surrounds.
Letter references are to figure r1001 1 which shows examples of typical construction.
2114 3 masonry built fireplaces 4114 3 10 all combustible mantels and similar trim shall be kept at least 6 inches from the fireplace opening.
The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.
This table provides a summary of major requirements for the construction of masonry chimneys and fireplaces.
All combustible mantel surrounds and shelves must be kept at least 12 inches from the opening of your fireplace top and sides.
Maximum 1 1 2 projection at 2 minimum clearance.
Installation of steel fireplace units with solid masonry to form a masonry fireplace is permitted when installed either in accordance with the requirements of their listing or the requirements of this section.
P36 10 p36e 10 gas fireplace min.
Installing a fireplace means meeting the code set by local governments.
Parts of the mantel assembly located along the sides of the fireplace opening which project more than 1 1 2 inches 38mm from the face of the fireplace shall have additional clearance equal to the projection extension beyond 1 1 2 inches.
California building codes for fireplaces.
The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures.
Steel fireplace units incorporating a steel firebox lining shall be constructed with steel not less than 1 4 inch 6 4 mm thick and an air circulating chamber that is ducted to the.
32 1016mm to ceiling regency mantel leg clearances combustible mantel leg clearances as per diagram.